Design Proposal For MITICA Cryogenic Plant (Contributo in atti di convegno)

Type
Label
  • Design Proposal For MITICA Cryogenic Plant (Contributo in atti di convegno) (literal)
Anno
  • 2012-01-01T00:00:00+01:00 (literal)
Alternative label
  • Valente, Matteo; Fellin, Francesco; Haas, Horst; Hanke, Stefan; Scannapiego, Matthieu; Zaccaria, Pierluigi (2012)
    Design Proposal For MITICA Cryogenic Plant
    in 12th Cryogenics IIR International Conference, Dresden, Germany, Sep 11-14, 2012
    (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#autori
  • Valente, Matteo; Fellin, Francesco; Haas, Horst; Hanke, Stefan; Scannapiego, Matthieu; Zaccaria, Pierluigi (literal)
Pagina inizio
  • 34 (literal)
Pagina fine
  • 39 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#url
  • http://www.scopus.com/record/display.url?eid=2-s2.0-84899427762&origin=inward (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#titoloVolume
  • Refrigeration Science and Technology (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#numeroVolume
  • 2012 (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#volumeInCollana
  • 2012 (literal)
Rivista
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#pagineTotali
  • 6 (literal)
Note
  • ISI Web of Science (WOS) (literal)
  • Scopu (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#affiliazioni
  • 1,2,6 : Consorzio Rfx, Padova, Italy; / 3-5 : Karlsruhe Institute of Technology. (literal)
Titolo
  • Design Proposal For MITICA Cryogenic Plant (literal)
Http://www.cnr.it/ontology/cnr/pubblicazioni.owl#isbn
  • 9782913149939 (literal)
Abstract
  • The MITICA Neutral Beam Injector, under construction in Padua at Consorzio RFX, will be equipped with a large cryosorption pump (composed by two halves). The cryopump, installed inside the MITICA Beam Line Vessel, will be supplied by a dedicated cryogenic plant with gaseous Helium (GHe) at 80 K and super critical Helium (ScHe) at 4.6 K. The design proposal for MITICA cryogenic plant is described in this paper. The cryogenic plant is divided in two main closed circuits: the 4.6 K circuit and the 80 K circuit. The first one is supplied by a Helium refrigerator via a LHe control cryostat acting as a thermal buffer due to the variable pulsed heat loads expected during MITICA operation. The second circuit is supplied by an 80 K facility where the refrigeration power is given by liquid nitrogen (LN2). Due to the expected large LN2 consumptions, a Nitrogen refrigerator is foreseen to recover and re-liquefy the evaporated LN2. (literal)